JNACSISSN:2582-3817

IoT-Based Telepresence Medical Robot (MBot) with Integrated Physiological Monitoring and Zero-Trust Security Architecture for Remote Healthcare Delivery

Abstract

Access to qualified medical practitioners remains a critical challenge in developing nations, particularly in rural and remote regions where healthcare infrastructure is limited and physician mobility is constrained by geography and resource availability. The World Health Organization projects a deficit of approximately 10 million health workers by 2030, with the burden disproportionately shouldered by low- and middle-income countries. This paper presents the design, implementation, and comprehensive performance evaluation of MBot, an Internet of Things (IoT)-enabled telepresence medical robot engineered to bridge the access gap by integrating mobility, physiological monitoring, secure communication, and automated clinical alerting in a single low-cost platform. MBot combines a four-wheel drive locomotion system with a dual-Arduino microcontroller architecture, an onboard physiological sensor suite comprising the MAX30102 heart-rate and pulse-oximetry module and the MLX90614 non-contact infrared temperature sensor, a 20×4 LCD display, and an IP camera for live video consultation. A zero-trust security architecture implements hardware-based cryptographic key storage and mutual TLS authentication across LoRaWAN-GSM hybrid communication channels, achieving a 41% reduction in successful breach attempts compared to legacy certificate-based approaches. When patient vitals breach clinical thresholds—BPM below 60 or above 130, SpO2 below 90%, or body temperature exceeding 100°F—the system activates an audible alarm and dispatches an automated status message to the supervising physician via GSM or FHIR-REST API endpoints. Bench-testing against FDA-cleared clinical reference instruments demonstrates temperature measurement accuracy within ±0.3°C, SpO2 deviation of ±1%, and heart-rate accuracy of ±2 BPM—all within internationally recognized clinical standards (IEC 80601-2- 56, ISO 80601-2-61). This work demonstrates that tightly integrated IoT, robotics, wireless communication technologies, and zero-trust security can meaningfully extend primary healthcare reach without demanding permanent physician presence, while meeting clinical standards and regulatory requirements for patient data protection.

References

  • World Health Organization, Health workforce; WHO Global Health Observatory, 2020. [Online]. Available: https://www.who.int/data/gho/data/themes/health-workforce
  • P. Garcia-Basteiro et al., Health workforce deficits in sub-Saharan Africa, The Lancet Psychiatry, vol. 8, no. 6, pp. 489–491, 2021.
  • J. Dario et al., Medical Robots in Hospital and Community Settings During COVID-19, IEEE Robotics & Automation Magazine, vol. 28, no. 2, pp. 102–110, 2021.
  • Boston Dynamics, Spot in Healthcare: Remote Patient Triage, Case Study, 2021. [Online]. Available: https://www.bostondynamics.com
  • L. Yao et al., Deployment of Medical Robots in Hospital Ward Rounds: A Multi-Centre Evaluation in China, Int. J. Robotics Research, vol. 40, no. 12, pp. 1440–1456, 2021.
  • M. J. Smith et al., Communication Quality in Robot-Mediated Healthcare: A Systematic Review, Telemedicine & e-Health, vol. 27, no. 8, pp. 896–910, 2021.
  • K. Rahman et al., Rural Telemedicine Infrastructure Challenges in Low-Income Settings, Global Health Action, vol. 13, article 1838404, 2020.
  • K. Ito, S. Sugano, and H. Iwata, Portable and Attachable Tele-Echography Robot System: FASTele, in Proc. 32nd Annual Int. Conf. IEEE EMBS, Buenos Aires, 2010, pp. 5461–5464.
  • R. Murai et al., A novel visible light communication system for enhanced control of autonomous delivery robots in hospitals, in Proc. IEEE/SICE Int. Symp. System Integration (SII), 2012, pp. 510–515.
  • J. Chen et al., WiFi-based Indoor Positioning: A Comparative Performance Analysis, IEEE Sensors J., vol. 21, no. 16, pp. 17854–17867, 2021.
  • M. Ali, A. Asim Ali, A. Taha, I. B. Dhaou, and T. N. Gia, Intelligent Autonomous Elderly Patient Home Monitoring System, in Proc. IEEE ICC, Shanghai, 2019, pp. 1–6.
  • N. Gorment, A. Selamat, L. Cheng, and O. Krejcar, Machine Learning Algorithm for Malware Detection: Taxonomy, Current Challenges, and Future Directions, IEEE Access, vol. 11, pp. 141045–141089, 2023.
  • S. Bakhri, E. Rosiana, and R. C. Saputra, Design of low cost pulse oximetry based on Raspberry Pi, J. Phys.: Conf. Series, vol. 1501, article 012043, 2020.
  • X. Chen, S. Zhou, and L. Wang, Edge Computing Framework for Distributed Healthcare IoT Systems, IEEE Trans. Industrial Informatics, vol. 17, no. 4, pp. 2891–2902, 2021.
  • HL7 International, FHIR R4.0.1 Standard, https://www.hl7.org/fhir/r4/, 2023.
  • M. Thompson et al., Impact of FHIR Standardization on EHR Integration Times and Data Quality, J. American Medical Informatics Assoc., vol. 28, no. 3, pp. 501–508, 2021.
  • NIST, Zero Trust Architecture, NIST Special Publication 800-207, 2020. [Online]. Available: https://nvlpubs.nist.gov/nistpubs/SpecialPublications/NIST.SP.800-207.pdf
  • IEEE 802.11ac, Wireless LAN Medium Access Control (MAC) and Physical Layer (PHY) Specifications, 2013.
  • Semtech Corporation, LoRaWAN Specification, Version 1.1, 2020.
  • GSM Association, GSM Technical Specifications, Release 15, 2021.
  • A. Pogue et al., Photoplethysmography Signal Processing for Heart Rate and SpO2 Measurement, IEEE Sensors J., vol. 21, no. 10, pp. 11845–11856, 2021.
  • Nonin Medical, OnySat Series Reference, Technical Data Sheet, 2021.
  • IEC 80601-2-56:2017, Medical Electrical Equipment—Part 2-56: Particular Requirements for the Basic Safety and Essential Performance of Clinical Temperature Monitoring Devices, 2017.
  • ISO 80601-2-61:2017, Medical Electrical Equipment—Part 2-61: Particular Requirements for Basic Safety and Essential Performance of Pulse Oximeter Equipment, 2017.
  • J. Rose et al., Communication Protocol Performance in Hospital Wireless Networks, Health Informatics J., vol. 27, no. 3, article 14604061211019850, 2021.
  • K. Seifert et al., Zero-Trust Network Architecture for Healthcare IoT, IEEE J. Biomedical & Health Informatics, vol. 25, no. 8, pp. 3217–3228, 2021.
  • V. Ashton, That Internet of Things, RFID Journal, vol. 22, pp. 97–114, 2009.